Enquiry Now

+88 02 222284773

GET A QUOTE
Lab Equipment

Techange BOD Incubator Supplier in Bangladesh

Techange BOD incubator system with a mercury-free 6-sample pressure sensor set and a temperature-controlled cabinet for BOD tests in ETP and STP labs, supplied with setup help and after-sales support by Techno Bangla Creation.

0 ~ 4000 mg/LBOD Test Range
6 SamplesIndependent Sensor Heads
20 ± 1 °CCulture Temperature
Techange BOD incubator six-bottle mercury-free sensor set
Techange BOD incubator cabinet supplied in Bangladesh
Brand: TechangeMercury-Free
Product Overview

What Is a BOD Incubator?

A BOD incubator holds water samples at a steady 20 °C while bacteria use up the oxygen in them. The oxygen used over five days is the BOD5 value. The Techange system pairs six battery-powered pressure sensor heads with a temperature-controlled cabinet, and it measures oxygen use without mercury.

BOD is not COD. BOD shows only the load that bacteria can consume, which is what a biological ETP treats. For a faster chemical test, see our Techange COD analyzer. Our ETP plant page covers complete treatment plants.

  • Mercury-free differential pressure (manometric) detection
  • Six samples, each with its own detection, control and display
  • Test cycle of 1 to 7 days, with data stored for 10 years
  • Setup help and after-sales support in Bangladesh
Request a Quotation
Specifications

Techange BOD Incubator Specifications

Type
BOD incubator with mercury-free pressure sensor set
Detection Method
Mercury-free differential pressure method
Test Range
0 ~ 4000 mg/L
Resolution
0.1 mg/L
Accuracy
±8%
Samples
6 samples, each with independent detection, control and display
Data Storage
10 years
Test Cycle
1 ~ 7 days
Sampling Points
Up to 60 per period
Battery Life
About 1 year
Culture Temperature
20 ± 1 °C
Other Features
Dilution detection capability and automated testing without operator supervision
Brand
Techange

Cabinet size, cooling system, power rating and accessories are not listed in the catalogue. Ask us what is included in your quotation.

Comparison

Manometric vs Dilution BOD Method

Two standard ways to measure BOD5. The Techange system uses the manometric (pressure) method.

Manometric versus dilution BOD method comparison
FeatureManometric (Pressure)Dilution (DO)
PrincipleOxygen use lowers the air pressure in a closed bottle and a sensor reads the dropDissolved oxygen is measured before and after 5 days
Standard methodRespirometric method, for example Standard Methods 5210 D5-day BOD test, Standard Methods 5210 B
Sample dilutionUsually none, so one bottle covers a wide rangeNeeded when oxygen demand is high
DataReadings stored automaticallyManual DO readings and calculation
Stirring and CO₂Needs stirring, and an alkali absorbs CO₂Needs dilution water and a DO meter
Best fitRoutine ETP and STP lab work with several samplesReference tests in labs with DO meters

Descriptions follow common method standards and maker guides. Always confirm details on the datasheet of the exact model.

How It Works

How Does a Mercury-Free BOD System Work?

  1. Measure the SamplePour the sample volume for your expected BOD range into a bottle and add a nitrification inhibitor if needed.
  2. Add Stirrer and AbsorberDrop in a stirring rod and place an alkali absorber in the seal cup to take up CO₂.
  3. Fit the Sensor HeadScrew the sensor head on tight and start the test. The head records pressure on its own battery.
  4. Incubate at 20 °CPlace the bottles in the cabinet at 20 ± 1 °C for the test period, 5 days for BOD5.
  5. Read the ResultBacteria use oxygen, CO₂ is absorbed and pressure falls. The head converts the drop to mg/L.
Why Choose It

Key Benefits of the Techange BOD Incubator

A cleaner, more automatic way to run the BOD test.

  • Mercury-free pressure detection removes the mercury waste of old manometers
  • Six independent sample channels, each with its own control and display
  • Wide range, 0 to 4000 mg/L, with dilution detection capability
  • Battery-powered heads store results for up to 10 years
  • Smart control runs a full test without operator supervision
  • Test cycles of 1 to 7 days suit BOD5 or BOD7 work
Bangladesh Limits

BOD Limits and Typical Effluent in Bangladesh

BOD5 is the number your ETP is judged on.

ECR 2023 BOD5 Limit
30 mg/L for textile wastewater to inland surface water, cut from 100 mg/L under the earlier rules
ECR 2023 COD Limit
200 mg/L
Test Conditions
BOD5 means 5 days at 20 °C, so the cabinet must hold its temperature steadily
Untreated Textile Effluent
Bangladeshi studies report BOD of about 70 to 850 mg/L
Instrument Range
This system reads 0 to 4000 mg/L, which covers raw and treated samples

Limits differ by industry and discharge point. Check your category with the Department of Environment.

Decision Guide

Is a BOD Incubator Right for You?

Choose a BOD Incubator When

  • You must report BOD5 for DoE or buyer audits
  • You run several samples at once and want automatic data
  • You want to avoid mercury in the lab
  • You need to see how biodegradable your effluent is
  • Your ETP has a biological stage that you must keep stable

Use Another Test When

  • You need a result in a few hours: use the Techange COD analyzer
  • You need continuous readings in a tank: see the EMEC online analyzer
  • You need dilution-method data for a legal reference test: ask the regulator which method it accepts
Applications

Where Are BOD Incubators Used?

Any lab that must show how much oxygen bacteria need to clean the water.

  • ETP Biological Stage
  • STP Inlet and Outlet
  • Textile Dyeing Wastewater
  • Pharmaceutical Effluent
  • Food and Beverage Effluent
  • River Water Monitoring
  • Aquaculture Water
  • University Labs
  • Research and Development
Buyer's Guide

How to Choose a BOD Incubator

Share these details with our engineers and we will recommend a suitable setup.

  • Samples per week. One run tests 6 samples. Plan runs against your inlet, outlet and process points.
  • Expected BOD. Tell us the range so we can advise sample volumes. Higher BOD needs a smaller sample.
  • Consumables. Ask about nitrification inhibitor, absorber chemical, stirring rods and bottles.
  • Cabinet and room. Confirm cabinet capacity, cooling and power, and give the unit ventilation so it can hold 20 °C in a hot room.
  • Checking accuracy. Run a check standard, such as a glucose-glutamic acid solution, now and then and log the results.
Need a BOD incubator? Tell us how many samples you test and your expected BOD range. Our engineers reply with a free quotation. +880 1716 825385 marketing@technocreationbd.com
FAQ

Frequently Asked Questions

What is a BOD incubator?

A BOD incubator is a cabinet that keeps samples at a constant 20 °C while bacteria use up oxygen. It is used for the 5-day biochemical oxygen demand test on wastewater. Unlike a normal incubator it can cool as well as heat, so it holds its temperature even in a hot room.

What is the use of a BOD incubator?

Its main use is BOD testing of effluent, sewage and river water, which shows how much oxygen bacteria need to break down organic matter. ETP and STP labs use it to check treatment and report to authorities. It is also used in microbiology work that needs a steady low temperature.

Why is BOD tested at 20 °C for 5 days?

The 20 °C and 5-day conditions come from British river conditions and are now the universal reference. A steady temperature matters because bacterial oxygen use changes with temperature. The Techange system holds 20 ± 1 °C and also supports test cycles of 1 to 7 days.

What is the difference between BOD and COD?

BOD measures the oxygen bacteria use over about 5 days, so it shows biodegradable organic load. COD measures all chemically oxidisable matter in a few hours and is usually higher. Comparing the two shows how biodegradable effluent is and which treatment suits it.

How does mercury-free BOD measurement work?

The sample sits in a closed bottle with air above it. Bacteria use oxygen and make CO₂, which an alkali absorbs, so air pressure drops. An electronic pressure sensor reads the drop and converts it to mg/L of BOD. Older manometers used mercury, which this system avoids.

What is a nitrification inhibitor?

A nitrification inhibitor, such as allylthiourea, stops nitrifying bacteria from using oxygen to convert ammonia. Without it, the reading includes this extra oxygen use and is not true BOD. It matters most for low-range samples, such as treated effluent, so ask us about the right dose.

How many samples can the Techange BOD incubator test?

The catalogue lists 6 samples per run, each with independent detection, control and display, and up to 60 sampling points per period. Results are stored for 10 years. For more samples per week, run several batches or ask us about extra sensor sets.

How can I get a quotation for the Techange BOD incubator?

Send your number of samples per week, expected BOD range and lab space details to Techno Bangla Creation by phone or email. Our engineers confirm what is included, such as the cabinet and consumables, and reply with a free quotation for your ETP, STP or WTP laboratory.