Rags, wipes and fibres kill ordinary sewage pumps. The Evergush EFK submersible cutter sewage pump shreds them at the impeller with a tungsten-tipped cutter, then pushes the slurry through 2" to 4" pipework, backed by Techno Bangla Creation Ltd. local installation and after-sales support.

Up to 1200 LPMCapacity
Up to 35 MMax Head
0.5 ~ 7.5 HPPower
EFK submersible cutter sewage pump
Evergush submersible sewage pump range
Brand: Evergush Origin: Taiwan
Product Overview

What Is an EFK Cutter Sewage Pump?

An An EFK submersible cutter sewage pump is an Evergush (Taiwan) pump with a tungsten-tipped cutter on its impeller. It sits underwater in a sump, shreds rags and fibrous solids, and discharges through a 2" to 4" pipe up to 35 m head and 1200 LPM.

A standard vortex (non-clog) submersible sewage pump uses an open or recessed impeller to pass solids whole, with free passage reported in roughly the 45 to 80 mm range on comparable models from major manufacturers. The EFK's cutter instead reduces solids first, which suits smaller discharge pipework and higher-lift, longer-run applications. Browse Evergush's full EF, EFD and EFA series for the non-cutter options.

  • Tungsten-tipped cutter impeller resists wear from hard objects
  • IP68 motor protection for continuous submersion (IEC 60529)
  • Dual mechanical seals plus an auto-cut thermal overload protector
  • Installation and after-sales support in Bangladesh
Request a Quotation
Specifications

EFK Cutter Sewage Pump Specifications

Output
0.5 ~ 7.5 HP
Motor Protection
IP68 (continuous submersion, per IEC 60529)
Insulation Class
F
Pole
2P
Voltage
1-phase 110 or 220V, 60Hz (0.5 ~ 2HP) · 3-phase 220 or 380V, 60Hz · 1-phase 220 ~ 240V, 50Hz (0.5 ~ 2HP) · 3-phase 380 ~ 415V, 50Hz
Discharge
2" ~ 4"
Max Head
35 M
Max Capacity
1200 LPM (about 72 m³/hr)
Cutter
Tungsten-tipped impeller cutter
Seal
Dual mechanical seals, epoxy resin cable base, auto-cut thermal protector
Brand
Evergush, EFK Series
Origin
Taiwan

Exact head, capacity and voltage depend on the exact model you select. Send us your required head, flow and discharge pipe size and our engineers will confirm the right EFK model.

How It Works

How an EFK Cutter Pump Works

  1. SubmersionThe pump sits fully submerged in the wet well or sump, sealed to IP68 for continuous immersion.
  2. IntakeSewage, including rags and soft solids, is drawn into the pump casing.
  3. Cutting ActionThe tungsten-tipped cutter on the impeller shreds solids before they reach the impeller vanes.
  4. DischargeThe now-shredded slurry is pumped out through 2" to 4" discharge pipework, even over a long or high-lift run.
  5. ProtectionDual mechanical seals and an auto-cut thermal protector guard the motor against seal failure and overheating.
Why Choose It

Key Benefits

Clogging is the most common cause of sewage pump downtime, so the cutter design matters.

  • Tungsten-tipped cutter resists wear and shreds rags, fibrous waste and soft solids
  • IP68-rated motor built for continuous submersion
  • Dual mechanical seals plus auto-cut thermal protection against motor burnout
  • Max head up to 35 M suits lift stations and long discharge runs
  • Compact 2" to 4" discharge fits smaller-diameter pipework
  • Local engineering, installation and after-sales support from Techno Bangla
Decision Guide

Which Sewage Pump Fits Your Site?

Choose an EFK Cutter Pump When

  • The waste stream regularly contains rags, cloth, or fibrous material
  • Discharge pipework is narrow (2" to 4") or runs a long distance
  • You need high lift, such as a multi-storey building or sewer force main
  • The site is a hospital, school, livestock farm or similar institutional source
  • Unattended, continuous operation is required

Choose a Standard Vortex Pump When

  • Solids are mostly soft, grit or small, without heavy rag content
  • A larger discharge pipe diameter is already available
  • Lower upfront cost matters more than cutting capability
  • The wet well is large, such as a municipal pumping station
  • See Evergush's full EF, EFD and EFA series for the non-cutter options.
Applications

Where EFK Cutter Pumps Are Used

Anywhere sewage or wastewater contains rags, fibrous waste or other obstacles.

  • Hospital Sewage
  • School & Institutional Drainage
  • Livestock & Poultry Farm Waste
  • Building & Apartment Lift Stations
  • Industrial Plant Drainage
  • Subway & Tunnel Dewatering
  • STP Lift Stations
Buyer's Guide

How to Choose the Right Sewage Pump

Share these details with our engineers and we will recommend a suitable EFK model.

  • Required head and capacity. State the vertical lift and the flow rate needed, in LPM or m³/hr, at peak load.
  • Discharge pipe size. Confirm whether your line is 2", 3" or 4", since this affects which EFK model fits.
  • Solids content. Tell us if the waste stream carries rags, cloth, sanitary items or livestock manure, so the cutter and motor size can be matched.
  • Power supply. Confirm single-phase or 3-phase supply and voltage (110, 220, 380 or 415V) available at site.
  • Site type. A hospital, school, apartment building or farm each has a different duty cycle and access for maintenance.
Need help choosing? Tell us your required head, capacity and discharge pipe size. Our engineers reply with a free quotation. +880 1716 825385 marketing@technocreationbd.com
FAQ

Frequently Asked Questions

What is an EFK submersible cutter sewage pump?

It is an Evergush (Taiwan) submersible pump with a tungsten-tipped cutter on the impeller. It shreds rags and fibrous solids before they reach the discharge pipe, which lets it work in narrow 2" to 4" lines.

Can an EFK cutter pump shred wipes, plastic bags and sanitary waste?

The cutter is built to break up soft, fibrous waste such as rags and wipes. Heavy plastic sheeting and hard items can still wrap or jam any pump, so fit a screen upstream and tell us what your drains carry.

What is the difference between a cutter pump and a grinder pump?

Cutter pumps typically have a cutting edge on the impeller and suit higher flows. Grinder pumps typically macerate solids into a fine slurry at low flow and high head, often for pressure sewer lines. Confirm each model’s duty on its datasheet.

What does IP68 mean on an EFK pump?

IP68 means the motor is dust-tight and rated for continuous submersion. The exact depth and duration are set by the manufacturer, so check the datasheet’s submersion limit before choosing your sump depth.

Do I need a single-phase or three-phase EFK pump in Bangladesh?

On 50 Hz supply, the EFK series offers 1-phase 220–240 V for 0.5 to 2 HP, and 3-phase 380–415 V across the range. Choose 3-phase for larger motors if your site has it.

How do I work out the flow and head I need?

Add the vertical lift to the pipe friction loss to get total head. Then pick a model whose curve delivers your flow at that head. The 35 m maximum head and 1200 LPM maximum flow do not occur at the same time.

How long does the cutter last, and what upkeep does it need?

The tungsten tip resists wear, but sand, grit and hard objects wear any cutter faster. Inspect the cutter and impeller on a regular schedule and keep a spare. Actual life depends on your waste.

Which sites use EFK pumps in Bangladesh?

EFK pumps suit hospitals, schools, apartment lift stations, livestock and poultry farms, and plant drainage, anywhere rags and fibres reach the sump. Send your discharge size and solids type and we match the model.